This alert is obsolete. GTW_w175_low12VPower is now an unused alert prefix as of 2019.40. If GTW_w175_low12VPower appears on the vehicle or in the logs, update the firmware to the current version.

This occurs when signal ETH_IBS_voltage (voltage measured by the IBS or E-Fuse) is below 12.0V for 5 seconds and is due to a power supply issue such as a poor connection, DCDC error or HV not enabling.

**Important: This alert does not mean there is an issue with the 12V battery - Please do not replace the 12V battery as a result of this alert.**

NOTE: there is presently a FW bug causing this alert to briefly trigger upon wakeup / just after the precharge sequence - it is described in Article #49353